Model | Max. input power | Melting capacity |
Input voltage | Working frequency | Output current | Duty | Requirement of cooling water |
DL-15 | 7Kw | 0.1~2kg | Single phase, 220v±20%, 50/60HZ | 30~100KHZ | 200-600A | 80% | >0.2MPa, 2-5L/min |
DL-25 | 15 Kw | 0.5~5kg | Three phase, 380v±20%, 50/60HZ | 200-1000A |
Model | DLG-03 | DLG-06 | DLG-10 | DLG-20 | DLG-30 | DLG-40 | DLG-60 | DLG-100 | DLG-160 |
Input Power (Kw) | 3 | 6 | 10 | 20 | 30 | 40 | 60 | 100 | 160 |
Input Power Voltage | Single phase, 220v±20%, 50/60HZ | Three phase, 380v±20%, 50/60HZ | |||||||
Working Frequency | 200~500KHZ | 0.5~1.1MHZ | 30~80KHZ | ||||||
Output Current (A) | 3-12 | 5-28 | 3-28 | 5-45 | 7-70 | 10-95 | 12-145 | 20-240 | 30-330 |
Output Voltage(V) | 70-550 | ||||||||
Duty | SI, 100% 24 hours non-stop |